AC-07-XXXX Series Displacement Transducers

AC-07-XXXX series displacement transducers are compact and rugged yet light in weight. These units are widely used for testing materials such as advanced composites, metals and polymers. They can also be used to test round and flat specimens to perform tensile, compression and cyclic tests. These extensometers include circuitry for auto-calibration against internal shunt reference, thus obviating the need for on-site calibration during installation.

 

Standard features

• Full strain 350Ω bridge construction
• Internal shunt reference for auto calibration
• Operational in both tension and compression modes (most models)
• Easy mounting on to the specimen
• Compatible with any strain gage electronics
• Digital auto calibration ensures no drift
• Rugged design

 

Applications

• Biomedical tests
• Testing of wire and thin sheet materials
• Tension, compression and cyclic testing on metal composites, high temperature and  polymers
• Compression testing on rock and concrete

 

rtext

Room Temperature Extensometer

htext

High Temperature COD Gage

dext

 Diametral Extensometer

rtcod

Room Temperature COD Gage

htcod

High Temperature COD Gage

avgext

Averaging Extensometer

     

 

 

 

 

 

 

 

                                                   

       

                                               

  Specifications

Excitation

5 VDC typical, 10 VDC or VAC max

Output

2.34 mV/V nominal depending on model

Linearity

<0.15% of full scale measuring range, depending on model

Temperature

0 - 1000 C

Cable

Integral flexi cable

 

 

Room Temperature Axial Extensometers

 

High Temperature Axial Extensometers

Model No.

Gage length, mm

Measuring range, mm

Model No.

Gage length, mm

Measuring range, mm

AC-07-1005

12.5

+/-0.5

AC-07-1105

10

+/-1.25

AC-07-1010

12.5

+/-1

AC-07-1110

12.5

+/-1.25

AC-07-1015

12.5

+/-2.5

AC-07-1115

12.5

+/-1.5

AC-07-1020

12.5

+/-5

AC-07-1120

12.5

+/-2.5

AC-07-1025

12.5

6.25/-3.1

AC-07-1125

25

8/-2

AC-07-1030

25

12.5/-6.35

AC-07-1130

25

12.5/-2.5

AC-07-1035

25

6/-3

Room Temperature Diametral Extensometers

AC-07-1040

50

+/-12.5

Model No.

Measuring range, mm

AC-07-1045

50

25/-12.5

AC-07-3005

2-4

AC-07-1050

75

12.5/-6.5

AC-07-3010

4-8

AC-07-1055

25

+/-2.5

AC-07-3015

8-12

Room Temperature Averaging Extensometer

AC-07-3020

12-16

AC-07-2005

100

+/-12.5

Room temperature shear extensometer

- AC-07-4005

AC-07-2010

50

+/-6

Room temperature shear extensometer

- AC-07-4015

 

Room Temperature COD Gages

 

High Temperature COD Gages

Model No.

Gage length, mm

Measuring range, mm

Model No.

Gage length, mm

Measuring range, mm

AC-07-0005

5

2/-1

AC-07-0105

5

3/-1

AC-07-0010

5

3/-1

AC-07-0110

10

AC-07-0015

10

4/-1

 

AC-07-0020

10

7/-1

 

AC-07-0025

12

12/-2

 

 

 

Note: Custom options available
         Room temperature extensometers and COD gages are rated for operating temperatures up to 80 deg.C
         High temperature extensometers and COD gages are rated for operating temperatures up to 1200 deg.C

Go to top